Maintenance

After disconnecting the device from power supply the general maintenance supposed to be done as follows:

1. Washing with warm water with addition of agents appropriate for washed surfaces

2. Removing impurities from the condenser by means of vacuum cleaner (from up to down - along the fins) with the frequency appropriate for prevailing environmental conditions so the flow of the cooling air through the condenser fins is not hampered (preferably once a month). Once a year (best before the first heatwaves) it is mandatory to clean the condenser with a vacuum cleaner and to purge the fins by means of compressed air from the fan side.

During condenser cleaning be careful not to distort the fins. Not following the recommendation from the 2 point causes increased energy consumption, decreased refrigeration efficiency of the device, aggregate overheating, which consequently may lead to failure.

It is not advisable to clean the condenser with a brush as it causes impurities penetration deep into condenser fins and finally block the air flow completely.

 

Maintenance of refrigerated counters - L-E, E1, F; L-E Max, E1 Max, F Max

clean_the_condenser_refrigerated_counters_le_e1_f_max_en.png

Maintenance of refrigerated counters - L-A, B, C, D

clean_the_condenser_refrigerated_counters_a_d_en.png

Maintenance of upright refrigerated cabinets with bottom mounted unit

clean_the_condenser_upright_refrigerated_cabinets_ad.png

Maintenance of upright refrigerated cabinets with top mounted unit

clean_the_condenser_upright_refrigerated_cabinets_ag_en.png

Maintenance of flower refigerator

clean_the_condenser_flower_refrigerator_en.png

Maintenance of multideck refrigerated displays

clean_the_condenser_rch-o_en.png

Maintenance of refrigerated confectionery display cases

clean_the_condenser_confectionery_display_cases_en.png